Hardware Observer
- Canonical BootStack Charmers
Channel | Revision | Published | Runs on |
---|---|---|---|
latest/stable | 128 | 26 Nov 2024 | |
latest/stable | 13 | 01 Nov 2023 | |
latest/candidate | 128 | 26 Nov 2024 | |
latest/candidate | 113 | 15 Oct 2024 | |
latest/candidate | 13 | 30 Oct 2023 | |
latest/edge | 149 | Today | |
latest/edge | 148 | Today | |
latest/edge | 119 | 11 Nov 2024 | |
latest/edge | 118 | 11 Nov 2024 | |
latest/edge | 15 | 03 Nov 2023 |
juju deploy hardware-observer
Deploy universal operators easily with Juju, the Universal Operator Lifecycle Manager.
Platform:
24.04
22.04
20.04
18.04
Metrics
The details of the metrics exposed by Hardware Observer for HPE Smart Array Controllers are as follows:
Metric Name | Description | Labels |
---|---|---|
ssacli_command_success | Indicates if the command is successful or not | |
ssacli_controllers | Total number of controllers | |
ssacli_controller_info | Shows information about controller part | slot, part, status |
ssacli_logical_drives | The number of logical drives in the slot | slot |
ssacli_logical_drive_info | Shows information about logical drive | slot, drive_id, status |
ssacli_physical_drives | The number of physical drives in the slot | slot |
ssacli_physical_drive_info | Shows information about physical drive | slot, drive_id, status |
Alerts
The details of the alerts that are provided by Hardware Observer for HPE Smart Array Controllers are as follows:
Alert Rule Name | Description | Severity |
---|---|---|
SsaCLICommandFailed | Failed to run ssacli. | critical |
SsaCLIControllerNotFound | ssacli controller not found. | warning |
SsaCLIControllerNotOK | ssacli controller status not Ok. | critical |
SsaCLILogicalDriveNotOK | ssacli logical drive status not Ok. | critical |
SsaCLIPhysicalDriveNotOK | ssacli physical drive status not Ok. | critical |