Platform:

stable 65

```
juju deploy openstack-telemetry
```

[Learn to deploy on juju >](https://juju.is/docs/juju/manage-applications)

* [Aodh](https://charmhub.io/openstack-telemetry/configurations/aodh)
* [Mysql Router](https://charmhub.io/openstack-telemetry/configurations/mysql-router)
* [Ceilometer](https://charmhub.io/openstack-telemetry/configurations/ceilometer)
* [Ceilometer Agent](https://charmhub.io/openstack-telemetry/configurations/ceilometer-agent)
* [Ceph Mon](https://charmhub.io/openstack-telemetry/configurations/ceph-mon)
* [Ceph Osd](https://charmhub.io/openstack-telemetry/configurations/ceph-osd)
* [Ceph Radosgw](https://charmhub.io/openstack-telemetry/configurations/ceph-radosgw)
* [Cinder](https://charmhub.io/openstack-telemetry/configurations/cinder)
* [Cinder Ceph](https://charmhub.io/openstack-telemetry/configurations/cinder-ceph)
* [Mysql Router](https://charmhub.io/openstack-telemetry/configurations/mysql-router)
* [Mysql Router](https://charmhub.io/openstack-telemetry/configurations/mysql-router)
* [Glance](https://charmhub.io/openstack-telemetry/configurations/glance)
* [Mysql Router](https://charmhub.io/openstack-telemetry/configurations/mysql-router)
* [Gnocchi](https://charmhub.io/openstack-telemetry/configurations/gnocchi)
* [Mysql Router](https://charmhub.io/openstack-telemetry/configurations/mysql-router)
* [Keystone](https://charmhub.io/openstack-telemetry/configurations/keystone)
* [Mysql Router](https://charmhub.io/openstack-telemetry/configurations/mysql-router)
* [Memcached](https://charmhub.io/openstack-telemetry/configurations/memcached)
* [Mysql Innodb Cluster](https://charmhub.io/openstack-telemetry/configurations/mysql-innodb-cluster)
* [Neutron Api](https://charmhub.io/openstack-telemetry/configurations/neutron-api)
* [Neutron Api Plugin Ovn](https://charmhub.io/openstack-telemetry/configurations/neutron-api-plugin-ovn)
* [Mysql Router](https://charmhub.io/openstack-telemetry/configurations/mysql-router)
* [Nova Cloud Controller](https://charmhub.io/openstack-telemetry/configurations/nova-cloud-controller)
* [Nova Compute](https://charmhub.io/openstack-telemetry/configurations/nova-compute)
* [Mysql Router](https://charmhub.io/openstack-telemetry/configurations/mysql-router)
* [Ntp](https://charmhub.io/openstack-telemetry/configurations/ntp)
* [Openstack Dashboard](https://charmhub.io/openstack-telemetry/configurations/openstack-dashboard)
* [Ovn Central](https://charmhub.io/openstack-telemetry/configurations/ovn-central)
* [Ovn Chassis](https://charmhub.io/openstack-telemetry/configurations/ovn-chassis)
* [Placement](https://charmhub.io/openstack-telemetry/configurations/placement)
* [Mysql Router](https://charmhub.io/openstack-telemetry/configurations/mysql-router)
* [Rabbitmq Server](https://charmhub.io/openstack-telemetry/configurations/rabbitmq-server)
* [Vault](https://charmhub.io/openstack-telemetry/configurations/vault)
* [Mysql Router](https://charmhub.io/openstack-telemetry/configurations/mysql-router)

[Learn about configurations >](https://juju.is/docs/juju/configuration#heading--application-configuration)

* bridge-interface-mappings | string

  A space-delimited list of key-value pairs that map a network interface MAC address or name to a local ovs bridge to which it should be connected.
  Note: MAC addresses of physical interfaces that belong to a bond will be resolved to the bond name and the bond will be added to the ovs bridge.
  Bridges referenced here must be mentioned in the `ovn-bridge-mappings` configuration option.
  If a match is found the bridge will be created if it does not already exist, the matched interface will be added to it and the mapping found in `ovn-bridge-mappings` will be added to the local OVSDB under the `external\_ids:ovn-bridge-mappings` key in the Open\_vSwitch table.
  An example value mapping two network interface mac address to two ovs bridges would be:
  br-internet:00:00:5e:00:00:42 br-provider:enp3s0f0
  Note: OVN gives you distributed East/West and highly available North/South routing by default. You do not need to add provider networks for use with external Layer3 connectivity to all chassis.
  Doing so will create a scaling problem at the physical network layer that needs to be resolved with globally shared Layer2 (does not scale) or tunneling at the top-of-rack switch layer (adds complexity) and is generally not a recommended configuration.
  Add provider networks for use with external Layer3 connectivity to individual chassis located near the datacenter border gateways by adding the MAC address of the physical interfaces of those units.
* debug | boolean

  Enable debug logging
* disable-mlockall | boolean

  Disable Open vSwitch use of mlockall().
  .
  When mlockall() is enabled, all of ovs-vswitchd's process memory is
  locked into physical RAM and prevented from paging. This avoids network
  interruptions but can lead to memory exhaustion in memory-constrained
  environments.
  .
  By default, the charm will disable mlockall() if it is running in a
  container. Otherwise, the charm will default to mlockall() enabled if
  it is not running in a container.
  .
  Changing this config option will restart openvswitch-switch, resulting
  in an expected data plane outage while the service restarts.
* dpdk-bond-config | string

  Default: :balance-tcp:active:fast

  Space delimited list of bond:mode:lacp:lacp-time, where the arguments meaning is:
  .
  \* bond - the bond name. If not specified the configuration applies to all bonds
  \* mode - the bond mode of operation. Possible values are:
  - active-backup - No load balancing is offered in this mode and only one of
  the member ports is active/used at a time.
  - balance-slb - Considered as a static load-balancing mode. Traffic is load
  balanced between member ports based on the source MAC and VLAN.
  - balance-tcp - This is the preferred bonding mode. It offers traffic load
  balancing based on 5-tuple header fields. LACP must be enabled
  at both endpoints to use this mode. The aggregate link will
  fall back to default mode (active-passive) in the event of LACP
  negotiation failure.
  \* lacp - active, passive or off
  \* lacp-time - fast or slow. LACP negotiation time interval - 30 ms or 1 second
* dpdk-bond-mappings | string

  Space-delimited list of bond:port mappings. The DPDK assigned ports will
  be added to their corresponding bond, which in turn will be put into the
  bridge as specified in data-port.
  .
  This option is supported only when enable-dpdk is true.
* dpdk-driver | string

  Kernel userspace device driver to use for DPDK devices, valid values
  include:
  .
  vfio-pci
  uio\_pci\_generic
  .
  Only used when DPDK is enabled.
* dpdk-runtime-libraries | string

  Space delimited list of additional DPDK runtime libraries that should
  be installed when DPDK is enabled.
  .
  By default, only the runtime libraries that are recommended with the
  dpdk libraries are installed. Environments that need additional libraries
  installed should include those library packages. The runtime libraries can
  be defined either by the full package name (e.g. librte-pmd-bnx2x20.0)
  or by the simple name (e.g. bnx2x). When providing the simple name, a
  search is done of the apt-cache for a name matching `librte-\*<name>\*`
  for installation and will install all matching packages that are found.
  .
  Only used when DPDK is enabled.
* dpdk-socket-cores | int

  Default: 1

  Number of cores to allocate to non-datapath DPDK threads per NUMA
  socket in deployed systems.
  .
  Only used when DPDK is enabled.
* dpdk-socket-memory | int

  Default: 1024

  Amount of hugepage memory in MB to allocate per NUMA socket in deployed
  systems.
  .
  Only used when DPDK is enabled.
  NOTE: Please check that the value set here is large enough to accommodate the MTU
  size being used. For more information please refer to
  https://docs.openvswitch.org/en/latest/topics/dpdk/memory/#shared-memory-calculations
* enable-auto-restarts | boolean

  Default: True

  Allow the charm and packages to restart services automatically when
  required.
* enable-dpdk | boolean

  Enable DPDK fast userspace networking; this requires use of DPDK
  supported network interface drivers and must be used in conjunction with
  the data-port configuration option to configure each bridge with an
  appropriate DPDK enabled network device.
* enable-hardware-offload | boolean

  Enable support for hardware offload of flows from Open vSwitch to
  supported network adapters.
  .
  Enabling this option will make use of the sriov-numvfs option to
  configure the VF functions of the physical network adapters detected in
  each unit.
  .
  This option must not be enabled with either enable-sriov or enable-dpdk.
  .
  NOTE: Changing this value will not perform runtime changes to hardware
  specific adaption. A reboot of the system is required to apply
  configuration.
* enable-sriov | boolean

  Enable SR-IOV NIC agent on deployed units; use with sriov-device-mappings
  to map SR-IOV devices to underlying provider networks. Enabling this
  option allows instances to be plugged into directly into SR-IOV VF
  devices connected to underlying provider networks alongside the default
  Open vSwitch networking options.
* enable-version-pinning | boolean

  Default: True

  OVN is a distributed system, and special consideration must be given to
  the process used to upgrade OVN.
  In order to successfully perform a rolling upgrade, the ovn-controller
  process needs to understand the structure of the database for the version
  you are upgrading from and to simultaneously.
  Rolling upgrades are supported as long as the span of versions used in
  the system is within the previous and the next upstream OVN LTS version.
  If you are upgrading across LTS boundaries you may need to use version
  pinning to avoid data plane outage during the upgrade.
* nagios\_context | string

  Default: juju

  A string that will be prepended to instance name to set the host name
  in nagios. So for instance the hostname would be something like:
  juju-myservice-0
  If you're running multiple environments with the same services in them
  this allows you to differentiate between them.
* nagios\_servicegroups | string

  Comma separated list of nagios servicegroups for the service checks.
* new-units-paused | boolean

  Start new units of the application as paused.
  .
  When set to 'true' newly deployed units of the application will install
  the charm and any packages required on the sytem, but keep any services
  from actually starting.
  .
  To start the services the operator must run the `resume` action on each
  unit.
  .
  This is useful for use with OpenStack for controlled unit by unit
  migration of deployments from the legacy Neutron ML2 OVS topology to the
  OVN topology. Both topologies make use of Open vSwitch and the 'br-int'
  integration bridge on the hypervisor and during a migration the operator
  may want to shut down and clean up after the ML2 OVS components before
  the `ovn-controller` takes over and reprograms the bridge flow rules.
* openstack-metadata-workers | int

  Default: 2

  When charm is related to OpenStack through the `nova-compute` relation
  endpoint, the Neutron OVN Metadata service will be activated on the host.
  .
  Use this configuration option to control the number of workers the
  Neutron OVN Metadata service should run.
  .
  Each of the workers will establish a connection to the OVN Southbound
  database. Events the worker respond to is for example the first time
  a hypervisor hosts an instance in a subnet, so the volume should be
  relatively low. If you set this number too high you may put an
  unnecessary toll on the OVN Southbound database server.
* ovn-bridge-mappings | string

  A space-delimited list of key-value pairs that map a physical network name to a local ovs bridge that provides connectivity to that network.
  The physical network name can be referenced when the administrator programs the OVN logical flows either by talking directly to the Northbound database or by interfacing with a Cloud Management System (CMS).
  Each charm unit will evaluate each key-value pair and determine if the configuration is relevant for the host it is running on based on matches found in the `bridge-interface-mappings` configuration option.
  If a match is found the bridge will be created if it does not already exist, the matched interface will be added to it and the mapping will be added to the local OVSDB under the `external\_ids:ovn-bridge-mappings` key in the Open\_vSwitch table.
  An example value mapping two physical network names to two ovs bridges would be:
  physnet1:br-internet physnet2:br-provider
  NOTE: Values in this configuration option will only have effect for units that have a interface referenced in the `bridge-interface-mappings` configuration option.
* ovn-monitor-all | boolean

  A boolean value that tells if ovn-controller should monitor all records
  of tables in the OVN\_Southbound database. If this option is set to false,
  ovn-controller will conditionally monitor only the records that are
  needed for the local chassis.
* ovn-source | string

  Overlay repository from which to install OVS+OVN.
  The default for this configuration option is determined at charm
  runtime.
  When charm is deployed into a fresh environment on Ubuntu
  20.04 (Focal Fossa), the default will be 'cloud:focal-ovn-22.03'.
  When charm is upgraded or deployed into a fresh environment
  on a different series the default will be to not use the
  overlay repository.
  To disable the overlay repository, set this option to 'distro'.
  Note that updating this setting to a source that is known to
  provide a later version of OVN will trigger a software
  upgrade.
* pmd-cpu-set | string

  Comma separated list of cpus used for DPDK datapath packet processing.
  The range and caret operators are supported.
  Example: 2,4,5-9,^7,16-23,^20,^22
  Only used when DPDK is enabled.
  NOTE: It is recommended to avoid overlap between datapath (pmd-cpu-mask)
  and non-datapath (dpdk-lcore-mask) cpus. The charm will go into blocked
  state if an overlap is detected.
* prefer-chassis-as-gw | boolean

  Prefer units of this application in CMS (Cloud Management System)
  scheduling of HA chassis groups (aka. gateways) over units of other OVN
  chassis applications present in this deployment.
  .
  By default the CMS will schedule HA chassis groups across all chassis
  with bridge- and bridge interface mappings configured.
  .
  This configuration option would allow you to influence where gateways are
  scheduled when all units have equal bridge- and bridge interface mapping
  configuration.
  .
  NOTE: If none of the OVN chassis named applications in the deployment
  have this option enabled, the CMS will fall back to schedule gateways to
  chassis with bridge- and bridge interface mapping configured.
  .
  NOTE: It is also possible to enable this option on several OVN chassis
  applications at the same time, e.g. on 2 out of 3.
* sriov-device-mappings | string

  Space-delimited list of SR-IOV device mappings with format
  .
  <provider>:<interface>
  .
  Multiple mappings can be provided, delimited by spaces.
* sriov-numvfs | string

  Default: auto

  Number of VF's to configure each PF with; by default, each SR-IOV PF will
  be configured with the maximum number of VF's it can support. In the case
  sriov-device-mappings is set, only the devices in the mapping are configured.
  Either use a single integer to apply the same VF configuration to all
  detected SR-IOV devices or use a per-device configuration in the following
  format
  .
  <device>:<numvfs>
  .
  Multiple devices can be configured by providing multi values delimited by
  spaces.
  .
  NOTE: Changing this value will have no effect on runtime configuration. A
  manual issue of the `netplan apply` command or reboot of the system is
  required to apply configuration.
* vpd-device-spec | string

  A list of specs used by the charm to identify a device to be used as a
  primary source of Vital Product Data (VPD) containing a NIC serial number.
  This option can be used to enable SmartNIC DPU support.
  .
  Based on the retrieved information the charm will set up a mapping between
  a chassis hostname and a unique card serial number of a NIC in the OVN
  southbound database. It can then used by the CMS to look up which chassis
  should service a port plugging request based on the information provided
  from a hypervisor host.
  .
  Multiple items can be specified in the list in order to allow for
  hosts with different kinds of hardware or to specify the order of
  precedence if multiple devices from the list are present on a host. This
  should not normally happen with DPUs that only have one chip exposed.
  .
  Examples: [{"bus": "pci", "vendor\_id": "15b3", "product\_id": "a2d6" },